Whatsapp Görüşmesi Başlat

Shunt Reactor

ORION Shunt Reactors are used to correct the power factor in capacitive networks. Due to network features such as over compensation in compensation systems and UPSs, long cable lines operating without load at night, the network is capacitively loaded and capacitive energy penalty is paid, voltage rises and generators are card failures as a result of negative excitation. causes problems. Orion Shunt Reactors are manufactured from special silicon steel cores with high magnetic characteristics with air gaps.

Why Shunt Reactor Should Be Used?

Orion Energy Shunt Reactors are designed with the most innovative technologies in accordance with TS EN and European standards, with a long life and resistant to harsh operating conditions. It is produced from . to 50 kVAr. It provides energy efficiency by minimizing energy losses, sound and vibration with its design.
It has a special design with single-phase (Monophase) or three-phase (Three-phase) high permeability air gap.
There is the possibility of design and production for the desired current or power.
It is protected against moisture and provides quiet operation in the electrical panel.
TECHNICIAL SPECIFICATIONS

Reactor Type: Shunt Reactor, Dry Type.
Standards: TS-EN61558-1 and EN 61558-2-20
Quality System: ISO9001 / TSE approved and CE certified
Rated Voltage: 230V / 50 Hz 1Phase or 400V / 50Hz / 3Phase
Reactor Impeance Percentage: 100%
Reactor Impedance tolerance: +/- 5%
Linearity: 120%
Max. Continuous Current : 1.1x In
Protection Class :IP00
Insulation Class: F (155°C)
Environment :   Max. Temperature :40°C / Max. Elevation: 2000m / max. Relative Humidity: 95%
Cooling Type : AN  Natural Air
Insulation Level. : 3kV
Winding Material: Copper/Aluminum
Thermal Protection : 150°C / 3 phase series / 1 NC contact
Terminal : Terminal / Shoe / Copper Busbar
Varnish : Vacuum Dip Impregnation with F or -according to demand- H class special varnish.

MONOFAZE SHUNT REACTORS

  POWER
INDUCTANCE
NETWORK CURRENT
MODEL NO (kVAr) (mH) (V/Hz) (A)
ORMS-0.5 0.5 337 230/50 2.2
ORMS-1.0 1 169 230/50 4.3
ORMS-1.5 1.5 112 230/50 6.5
ORMS-2.0 2 84 230/50 8.7
ORMS-2.5 2.5 67 230/50 10.9
ORMS-3.0 3 56 230/50 13.0
ORMS-4.0 4 42 230/50 17.4
ORMS-5.0 5 33.7 230/50 21.7
ORMS-7.5 7.5 22.5 230/50 32.6
ORMS-10 10 16.8 230/50 43.5

TRİFAZE SHUNT REACTORS

  POWER INDUCTANCE NETWORK CURRENT
MODEL NO (kVAr) (mH) (V/Hz) (A)
ORTS-0.5 0.5 1019 400/50 0.7
ORTS-1.0 1 510 400/50 1.4
ORTS-1.5 1.5 340 400/50 2.2
ORTS-2.0 2 255 400/50 2.9
ORTS-2.5 2.5 204 400/50 3.6
ORTS-3.0 3 170 400/50 4.3
ORTS-4.0 4 127 400/50 5.8
ORTS-5.0 5 102 400/50 7.2
ORTS-7.5 7.5 68 400/50 10.8
ORTS-10 10 51 400/50 14.4
ORTS-15 15 34 400/50 21.7
ORTS-20 20 25.5 400/50 28.9
ORTS-25 25 20.4 400/50 36.1
ORTS-30 30 17.0 400/50 43.3
ORTS-40 40 12.7 400/50 57.7
ORTS-50 50 10.2 400/50 72.2
ORTS-75 75 6.8 400/50 108.0
ORTS-100 100 5.1 400/50 144.4
* We also have custom production for other inductance and power values. We reserve the right to make changes in dimensions.